Friskers
Model 26S
- Scintillation Detector
- Units: cps, cpm, µSv/h, mR/hr, dpm, Bq
Model 26
- Pancake GM Detector
- Units: cps, cpm
Model 26-1 Series
- Pancake GM Detector
- Units: cps, cpm, µSv/h, mR/hr, dpm, Bq
- Dose Equivalent Filter Option
Model 26-2
- Pancake GM Detector
- Units: cps, cpm
- 3 Alarm Levels
Model 26-3
- Pancake GM Detector
- Units: cps, cpm, µSv/h, mR/hr, dpm, Bq
- Dead-Time Correction Allowing Gamma Measurements up to 1000 mR/hr (1999 µSv/h)
General Purpose - Digital
Model 3003 Series
- Supports GM, Proportional,
- Scintillation & Neutron Detectors
Stores Up To 4 Detector Set-Ups - Internal Detector Option for Accumulated Dose
- Includes Data Logging Capability
Model 3014
- Supports GM, Proportional & Scintillation Detectors
- Internal Detector for Accumulated Dose
- Data Logging Capability
- Single Channel Analyzer (SCA) Capable
Model 3001
- Supports GM, Proportional & Scintillation Detectors
- Stores Up To 4 Detector Set-Ups
- Optional Data Logging Capability
Model 3002
- Supports Alpha-Beta Proportional & Scintillation Detectors
- Includes Data Logging Capability
Model 3000
- Supports GM, Proportional & Scintillation Detectors
- Optional Data Logging Capabilit
Model 30
- Attaches to Detector Allowing One-Handed Operation
- Supports GM, Proportional & Scintillation Detectors
Model 35
- Vehicle Mounted Digital Survey Meter
- Supports GM, Proportional & Scintillation Detectors
General Purpose - Analog
Model 3
- 4-Range Analog Survey Meter
- Supports GM & Scintillation Detectors
Model 3A
- 4-Range Analog Survey Meter
- Supports GM & Scintillation Detectors
- Alarm
Model 12
- 4-Range Analog Survey Meter
- Supports GM, Proportional & Scintillation Detectors
Model 14C
- 5-Range Analog Survey Meter
- Operates Two Detectors
- Internal: GM Detector (0 – 2000 mR/hr)
- External: Supports GM & Scintillation Detectors
Model 16
- 4-Range Analog Survey Meter
- Supports GM, Proportional & Scintillation Detectors
- Adjustable Window
Model 18
- 4-Range Analog Survey Meter
- Supports GM, Proportional & Scintillation Detectors
- Adjustable Window
- 3 Detector Setups
Model 2402
- 3-Range Analog Meter
- Supports GM & Scintillation Detectors
- Alarm
Model 2403
- 4-Range Analog Meter
- Supports GM & Scintillator Detectors
Computerized Survey Meters
Model 4404-16 Series
- Large Area Outdoor Survey Meter
- NaI Scintillator Detector
- Multi-Single-Channel Analyzers
- Data Logging Program
- Google Earth™ Compatible Files
Model 4600 Series
- 1 to 12 Detector Single Channel Analyzer
- Supports G-M, Proportional & Scintillator Detectors
- Independently Adjustable HV, Threshold, Window, Scaler Count Time & Output Time for Each Channel
- HV Range: 0 to 1500 V or 0 to 2500 V
Data Loggers
Model 3003 Series
- Supports GM, Proportional, Scintillation & Neutron Detectors
- Stores Up To 4 Detector Set-Ups
- Internal Detector Option for Accumulated Dose
- Includes Data Logging Capability
Model 3014
- Supports GM, Proportional & Scintillation Detectors
- Internal Detector for Accumulated Dose
- Data Logging Capability
- Single Channel Analyzer (SCA) Capable
Model 3001
- Supports GM, Proportional & Scintillation Detectors
- Stores Up To 4 Detector Set-Ups
- Optional Data Logging Capability
Model 3002
- Supports Alpha-Beta Proportional & Scintillation Detectors
- Includes Data Logging Capability
Model 3000
- Supports GM, Proportional & Scintillation Detectors
- Optional Data Logging Capability
Model 3005
- Auto-Ranging Digital Meter
- Internal Energy-Compensated GM Detector
- Range: Background to 50 mSv/h (5 R/hr), others available
- Includes Data Logging Capability
Model 3019
- Digital Meter
- Internal 2.5 x 1.9 cm (1 x 0.75 in.) CsI Scintillator Detector
- Sensitivity (137Cs): 17,500 cpm per µSv/h (175 cpm per µR/hr)
- Range: Background to 500 µSv/h (50 mR/hr)
- Alarms
Model 3192
- Digital Meter
- Internal 5.1 x 2.5 cm (2 x 1 in.) NaI Scintillator Detector
- Sensitivity (137Cs): 65,000 cpm per μSv/h (650 cpm per μR/hr)
- Range: Background to 50 μSv/h (0 to 5,000 μR/hr)
- Alarms
Model 2350-1
- 5-Range Digital Meter
- Supports GM, Proportional & Scintillator Detectors
- Stores 1000 Data Points
- Supports 16 Detector Setups
Model 2360
- For Alpha-Beta Surveying
- 4-Range Analog Meter with Digital Scaler LCD
- Supports Alpha-Beta Proportional & Scintillator Detectors
- Stores 550 Data Points
Specialized Meters
Model 194
- Energy-Flat Dose Equivalent Rate Meter
- Digital Display
- Internal Plastic Scintillator Detector
- Low Range: Background to 19.99 µSv/h (1999 µrem/hr)
- High Range: 1 to 1999 µSv/h (0.1 to 199.9 mrem/hr)
- Extended Version with Low-Energy Window
Model 3-97
- Gamma Survey
- 4-Range Analog Meter
- Internal NaI(Tl) Scintillator Detector
- Sensitivity (137Cs): 175 cpm per µR/hr
- External Model 44-38 GM Detector
- Sensitivity (137Cs): 1200 cpm per mR/hr
- Range: 0 µR/hr to 200 mR/hr
Model 3-98
- 125I & Alpha-Beta
- Gamma Survey
- 4-Range Analog Meter
- Internal Pancake GM Detector
- Sensitivity (137Cs): 3300 cpm per mR/hr
- External Model 44-3 NaI(Tl) Scintillator Detector
- Sensitivity (125I): 675 cpm per µR/hr
- Range: 0 to 500 kcpm
Model 195 with 43-132
- Alpha Survey
- Model 195 Digital Meter
- External Model 43-132 Alpha Ion Chamber Detector
Geiger Counters
Model 3005
- Auto-Ranging Digital Meter
- Internal Energy-Compensated GM Detector
- Range: Background to 50 mSv/h (5 R/hr), others available
- Includes Data Logging Capability
Model 5
- 5-Range Analog Meter
- Two Internal Energy-Compensated GM Detectors
- Range: 0 to 20 mSv/h (0 to 2000 mR/hr)
Model 6
- 3-Range Analog Meter
- Internal Energy-Compensated GM Detector
- Range: 0 to 10 mSv/h (0 to 1000 mR/hr)
Intrinsically Safe
Model 3-IS
- 4-Range Analog Meter
- Supports Select GM & Scintillator Detectors
Model 3-IS-1
- 4-Range Analog Meter
- Internal Energy Compensated GM Detector
Model 25-IS Series
- Intrinsically Safe
- Dose Rate and Accumulated Dose Alarms
- Range: 0.02 mSv/h to 9.99 Sv/h (2 mR/hr to 999 R/hr)
Ion Chambers
Model 9DP
- Color LCD Digital Meter
- Range: Background to 50 mSv/h (5 R/hr)
- Chamber Pressure: 9 atm (122 psig)
Model 9DP*
- Color LCD Digital Meter
- Range: Background to 50 mSv/h (5 R/hr)
- Chamber Pressure: 9 atm (122 psig)
- Provides ICRU-Based Ambient Dose Equivalent Measurements
Model 9DP-1
- Color LCD Digital Meter
- Range: 2 µSv/h to 500 mSv/h (200 µR/hr to 50 R/hr)
- Chamber Pressure: 2.5 atm (22 psig) [Non-HAZMAT]
Model 9DP-1*
- Color LCD Digital Meter
- Range: 2 µSv/h to 500 mSv/h (200 µR/hr to 50 R/hr)
- Chamber Pressure: 2.5 atm (22 psig) [Non-HAZMAT]
- Provides ICRU-Based Ambient Dose Measurements
Model 9-3
- 5-Range Analog Meter
- Range: 0 to 500 mSv/h (0 to 50 R/h)
- Temperature Compensated
- Retractable Beta Shield
Model 9-4
- 5-Range Analog Meter
- Range: 0 to 500 mSv/h (0 to 50 R/hr)
- Temperature & Pressure Compensated
- Retractable Beta Shield
Model 9-4RF
- RF Immunity
- 5-Range Analog Meter
- Range: 0 to 500 mSv/h (0 to 50 R/hr)
- Temperature & Pressure Compensated
- Retractable Beta Shield
Model 9-7
- Digital Meter
- Display Range: 0.001 R/hr to 19.99 kR/hr
- Four Available Detectors
- Replacement for Eberline Model RO-7
Model 9-7S
- Digital Meter
- 1.1 to 3.8 m (3.7 to 12.6 ft.) Telescoping Stainless Steel Pole
- Display Range: 0.001 R/hr to 19.99 kR/hr
- Four Available Detectors
Micro / MocroSV Meters
Model 3019
- Digital Meter
- Internal 2.5 x 1.9 cm (1 x 0.75 in.) CsI Scintillator Detector
- Sensitivity (137Cs): 17,500 cpm per µSv/h (175 cpm per µR/hr)
- Range: Background to 500 µSv/h (50 mR/hr)
- Alarms
Model 3192
- Digital Meter
- Internal 5.1 x 2.5 cm (2 x 1 in.) NaI Scintillator Detector
- Sensitivity (137Cs): 65,000 cpm per μSv/h (650 cpm per μR/hr)
- Range: Background to 50 μSv/h (0 to 5,000 μR/hr)
- Alarms
Model 19
- Linear Analog Meter
- 5 Selectable Ranges
- Internal 2.5 x 2.5 cm (1 x 1 in.) NaI Scintillator Detector
- Sensitivity (137Cs): 175 cpm per µR/hr
- Range: 0 to 5000 µR/hr
Model 19A
- Logarithmic Analog Meter
- Internal 2.5 x 2.5 cm (1 x 1 in.) NaI Scintillator Detector
- Sensitivity (137Cs): 17,500 cpm per µSv/h (175 cpm per µR/hr)
- Range: 0 to 5 µSv/h (0 to 500 µR/hr)
- Alarm
Model 192
- 4-Range Analog Meter
- Internal 5.1 x 2.5 cm (2 x 1 in.) NaI Scintillator Detector
- Sensitivity (137Cs): 650 cpm per µR/hr
- Range: 0 to 50 µSv/h (0 to 5000 µR/hr)
- Dual Action Alarm
Model 193
- 4-Range Analog Meter
- Supports Gamma Scintillator Detectors
- Dual Action Alarm
- Four Linear Ranges
Model 12S
- 4-Range Analog Meter
- Internal 2.5 x 2.5 cm (1 x 1 in.) NaI Scintillator Detector
- Sensitivity (137Cs): 175 cpm per µR/hr
- Range: 0 to 3000 µR/hr
Model 12SA
- 4-Range Analog Meter
- Internal 2.5 x 2.5 cm (1 x 1 in.) NaI Scintillator Detector
- Sensitivity (137Cs): 175 cpm per µR/hr
- Range: 0 to 3000 µR/hr
- Alarm
Model 2401-S
- Low-Level Gamma & X-Ray Survey
- 3-Range Analog Meter
- Internal 18 mm dia. CsI Scintillator Detector
- Sensitivity (137Cs): 100 cpm per µR/hr
- Range: 0 to 50 µSv/h (0 to 5000 µR/hr)
- Alarm
Neutrom Meters
Model 30-7 Series
- Digital Meter
- 3He Proportional Detector
- Moderator: 19.5 cm (7.7 in.) dia.
- Sensitivity (241AmBe): 4.5 cpm per µSv/h (45 cpm per mrem/hr) or 10 cpm per µSv/h (100 cpm per mrem/hr)
- Range: 0 to 99.9 mSv/h (0 to 9.99 rem/hr)
Model 3007 Series
- Digital Meter
- 3He Proportional Detector
- Moderator: 19.5 cm (7.7 in.) dia.
- Sensitivity (241AmBe): 4.5 cpm per µSv/h (45 cpm per mrem/hr) or 10 cpm per µSv/h (100 cpm per mrem/hr)
- Range: 0 to 100 mSv/h (0 to 10,000 rem/hr)
- Internal Detector Option for Exposure/Dose Measurements
Model 12-4-7
- 4-Range Analog Meter
- Moderator: 19.5 cm (7.7 in.) dia.
- Sensitivity (241AmBe): 10 cpm per µSv/h (100 cpm per mrem/hr)
- Range: 0 to 100 mSv/h (0 to 10,000 mrem/hr)
Model 30-4
- Digital Meter
- 3He Proportional Detector
- Moderator: 22.9 cm (9.0 in.) dia.
- Sensitivity (241AmBe): 10 cpm per µSv/h (100 cpm per mrem/hr)
- Range: 0 to 99.9 mSv/h (0 to 9.99 rem/hr)
Model 3004 Series
- Digital Meter
- 3He Proportional Detector
- Moderator: 22.9 cm (9,0 in.) dia.
- Sensitivity (241AmBe): 10 cpm per μSv/h (100 cpm per mrem/hr)
- Range: 0 to 100 mSv/h (0 to 10,000 rem/hr)
- Internal Detector Option for Exposure/Dose Measurements
Model 12-4
- 4-Range Analog Meter
- Model 42-31H 3He Proportional Detector
- Moderator: 22.9 cm (9.0 in.) dia.
- Sensitivity (241AmBe): 10,000 cpm per mSv/h (100 cpm per mrem/hr)
- Range: 0 to 100 mSv/h (0 to 10,000 mrem/hr)
Model 2241-4
- Digital Scaler-Ratemeter
- Model 42-31H 3He Proportional Detector
- Moderator: 22.9 cm (9.0 in.) dia.
- Sensitivity (241AmBe): 30 cpm per mrem/hr
- Range: 0 to 100 mSv/h (0 to 10,000 mrem/hr)
Model 375-31H
- Digital Area Monitor
- 3He Proportional Detector
- Moderator: 22.9 cm (9.0 in.) dia.
- Sensitivity: 10,000 cpm per mSv/h (100 cpm per mrem/hr)
- Range: 0 to 100 mSv/h (0 to 10 rem/hr)
Model 2363 with 42-41L
- Neutron and Gamma Detection
- Analog + Digital Scaler-Ratemeter
- External Model 42-41L PRESCILA Detector
- Neutron Sensitivity: 350 cpm per mrem/hr
- Range: 0.1 mrem/hr to 1 rem/hr
- Internal GM Detector
- Gamma Sensitivity: 1000 cpm per mR/hr
- Range: 1 µSv/h to 10 m Sv/h (0.1 mR/hr to 1 R/hr)
Model 15
- Neutron and Alpha-Beta-Gamma Detection
- 4-Range Analog Meter
- Model 42-14H 3He Proportional Detector
- Sensitivity (241AmBe): 55 cpm per mrem/hr
- Model 44-7 End-Window GM Detector
- Sensitivity (137Cs): 2100 cpm per mR/hr
- Range: 0 to 500,000 cpm
Pocket-Size Meters
Model 2401-EC
- Digital Meter
- 3He Proportional Detector
- Moderator: 19.5 cm (7.7 in.) dia.
- Sensitivity (241AmBe): 4.5 cpm per µSv/h (45 cpm per mrem/hr) or 10 cpm per µSv/h (100 cpm per mrem/hr)
- Range: 0 to 99.9 mSv/h (0 to 9.99 rem/hr)
Model 2401-ECA
- Digital Meter
- 3He Proportional Detector
- Moderator: 19.5 cm (7.7 in.) dia.
- Sensitivity (241AmBe): 4.5 cpm per µSv/h (45 cpm per mrem/hr) or 10 cpm per µSv/h (100 cpm per mrem/hr)
- Range: 0 to 100 mSv/h (0 to 10,000 rem/hr)
- Internal Detector Option for Exposure/Dose Measurements
Model 2401-EC2
- 4-Range Analog Meter
- Moderator: 19.5 cm (7.7 in.) dia.
- Sensitivity (241AmBe): 10 cpm per µSv/h (100 cpm per mrem/hr)
- Range: 0 to 100 mSv/h (0 to 10,000 mrem/hr)
Model 2401-EC2A
- Digital Meter
- 3He Proportional Detector
- Moderator: 22.9 cm (9.0 in.) dia.
- Sensitivity (241AmBe): 10 cpm per µSv/h (100 cpm per mrem/hr)
- Range: 0 to 99.9 mSv/h (0 to 9.99 rem/hr)
Model 2401-EW
- Digital Meter
- 3He Proportional Detector
- Moderator: 22.9 cm (9,0 in.) dia.
- Sensitivity (241AmBe): 10 cpm per μSv/h (100 cpm per mrem/hr)
- Range: 0 to 100 mSv/h (0 to 10,000 rem/hr)
- Internal Detector Option for Exposure/Dose Measurements
Model 2401-EWA
- 4-Range Analog Meter
- Model 42-31H 3He Proportional Detector
- Moderator: 22.9 cm (9.0 in.) dia.
- Sensitivity (241AmBe): 10,000 cpm per mSv/h (100 cpm per mrem/hr)
- Range: 0 to 100 mSv/h (0 to 10,000 mrem/hr)
Model 2401-P
- Digital Scaler-Ratemeter
- Model 42-31H 3He Proportional Detector
- Moderator: 22.9 cm (9.0 in.) dia.
- Sensitivity (241AmBe): 30 cpm per mrem/hr
- Range: 0 to 100 mSv/h (0 to 10,000 mrem/hr)
Model 2401-P DOSE
- Digital Area Monitor
- 3He Proportional Detector
- Moderator: 22.9 cm (9.0 in.) dia.
- Sensitivity: 10,000 cpm per mSv/h (100 cpm per mrem/hr)
- Range: 0 to 100 mSv/h (0 to 10 rem/hr)
Model 2401-S
- Neutron and Gamma Detection
- Analog + Digital Scaler-Ratemeter
- External Model 42-41L PRESCILA Detector
- Neutron Sensitivity: 350 cpm per mrem/hr
- Range: 0.1 mrem/hr to 1 rem/hr
- Internal GM Detector
- Gamma Sensitivity: 1000 cpm per mR/hr
- Range: 1 µSv/h to 10 m Sv/h (0.1 mR/hr to 1 R/hr)
Model 2402
- Neutron and Alpha-Beta-Gamma Detection
- 4-Range Analog Meter
- Model 42-14H 3He Proportional Detector
- Sensitivity (241AmBe): 55 cpm per mrem/hr
- Model 44-7 End-Window GM Detector
- Sensitivity (137Cs): 2100 cpm per mR/hr
- Range: 0 to 500,000 cpm
Model 2403
- Neutron and Alpha-Beta-Gamma Detection
- 4-Range Analog Meter
- Model 42-14H 3He Proportional Detector
- Sensitivity (241AmBe): 55 cpm per mrem/hr
- Model 44-7 End-Window GM Detector
- Sensitivity (137Cs): 2100 cpm per mR/hr
- Range: 0 to 500,000 cpm
Stretch Scopes
Model 3078 Series
- Digital Meter
- Extends to 4.7 m (15.3 ft.)
- Two External Energy-Compensated GM Detectors
- Version with Internal Energy-Compensated GM Detector
- Range: 1 µSv/h to 10 Sv/h (0.1 mR/hr to 1000 R/hr)
Model 79
- Digital Meter
- Extends to 4.5 m (14.75 ft.)
- Energy-Compensated GM Detector
- Range: 10 µSv/h to 10 Sv/h (1 mR/hr to 1000 R/hr)
Model 79/1
- Digital Meter
- Extends to 4.5 m (14.75 ft.)
- CsI(Tl) Scintillator Detector
- Range: 0.01 µSv/h to 500 µSv/h (1 µR/hr to 50 mR/hr)
Model 79-2
- Digital Meter
- Extends to 4.5 m (14.75 ft.)
- Internal Energy-Compensated GM
- Range: 0.001 mSv/h to 0.04 Sv/h (0.1 mR/hr to 4 R/hr)
Model 78
- Analog + Digital Meter
- Extends to 3.6 m (12 ft.)
- 2 Energy-Compensated GM Detectors
- Range: 0.1 mR/hr to 1000 R/hr
Model 78-1
- Analog + Digital Meter
- Extends to 3.6 m (12 ft.)
- 2 Energy-Compensated GM Detectors
- Range: 0.1 µSv/hr to 9999 mSv/hr
Model 78-6
- Analog + Digital Meter
- Extends to 3.6 m (12 ft.)
- NaI(Tl) Scintillator Detector
- Range: 0.01 to 50 µSv/h (1 to 5000 µR/hr)
Model 78-9
- Digital Meter
- Extends to 3.6 m (12 ft.)
- Pancake GM Detector
Model 9-7S
- Digital Meter
- 1.1 to 3.8 m (3.7 to 12.6 ft.) Telescoping Stainless Steel Pole
- Display Range: 0.001 R/hr to 19.99 kR/hr
- Four Available Detectors