Benchtop Meters
Model 3276
- Auto-Ranging Digital Meter
- Functions as a Frisker or an Area Monitor
- Supports GM, Proportional & Scintillation Detectors
- Adjustable Audio & Visual Alarms
- HV Range: 500 to 1500 V
Model 3277/1
- For Simultaneous Alpha & Beta Counting
- 7-in. Color Touch-Screen Display
- Supports Alpha-Beta Scintillation & Proportional Detectors
- Adjustable Audio & Visual Alarms
- HV Range: 400 to 2200 Vd
Model 177
- 4-Range Linear Analog Meter
- Supports GM & Scintillation Detectors
- Adjustable Audio & Visual Alarm
- HV Range: 400 to 1500 V
Model 177-50
- 5-Range Logarithmic Analog Meter
- Supports GM, Proportional & Scintillation Detectors
- Adjustable Audio & Visual Alarm
- HV Range: 400 to 2500 V
Model 177-56
- 4-Range Linear Analog Meter
- Operates with Two Detectors: Scintillator for Alpha, GM for Beta
- HV Range (Alpha): 400 to 1500 V
- HV (Beta): 900 V
Model 177-61
- 4-Range Linear Analog Meter
- Supports GM, Proportional & Scintillation Detectors
- Adjustable Audio & Visual Alarm
- HV Range: 400 to 2500 V
Model 177-84
- For Simultaneous Alpha & Beta Counting
- Dual 3-Range Logarithmic Analog Meters
- Supports Alpha-Beta Proportional & Scintillator Detectors
- Adjustable Audio & Visual Alarms
- HV Range: 200 to 1500 V
Model 4600 Series
- 1 to 12 Detector Single Channel Analyzer
- Supports G-M, Proportional & Scintillator Detectors
- Independently Adjustable HV, Threshold, Window, Scaler Count Time & Output Time for Each Channel
- HV Range: 0 to 1500 V or 0 to 2500 V
Dosimeters
Model 23
- X-ray and Gamma Radiation Monitoring
- Dose Rate and Accumulated Dose Alarms
- Range:
0.1 mrem/hr to 99.99 rem/hr
0.1 mrem to 99.99 rem
Model 23-1
- X-ray and Gamma Radiation Monitoring
- Dose Rate and Accumulated Dose Alarms
- Range:
0.001 mSv/h to 999.9 mSv/h
0.001 mSv to 999.9 mSv
Model AT-138
- X-ray and Gamma Radiation Monitoring
- Range: 0 to 200 mR
Model AT-138S
- X-ray and Gamma Radiation Monitoring
- Range: 0 to 2 mSv
Model AT-725
- X-ray and Gamma Radiation Monitoring
- Range: 0 to 5 R
Model K8
- Solid State Detector
- Alarms at 100 µSv/h (10 mR/hr)
Pulsers
Model 500
- Analog HV Display (0 to 2.5 kV)
- Digital Pulse Rate Display (1 to 9,900,000 cpm)
- Analog Pulse Amplitude Display (0 mV to 5 V)
Model 500-01
- Digital HV Display (0 to 1999 V)
Digital Pulse Rate - Display (1 to 9,900,000 cpm)
- Analog Pulse Amplitude Display (0 mV to 5 V)
Model 500-2
- Digital HV Display (0 to 1999 V)
- Digital Pulse Rate Display (1 to 9,900,000 cpm)
- Digital Pulse Amplitude Display (0 mV to 5 V)
Cases
Model 3000 Series
REM Ball Neutron Meter Cases
- Models : 12-4 | 12-4-7 | 30-4 |30-7 | 3007
REM Ball Neutron Meter Cases
- Models : 12-4 | 12-4-7 | 30-4 |30-7 | 3007